首页参展厂商展商动态产品汇总技术文章快速采购通道我的商务中心
您现在的位置:网上粉体展 > 分析仪器设备频道 > 动物实验仪器专场 > 电化学检测系统
厂商性质:生产商
商品人气:478
联系人:销售部
查看联系方式
我要留言
电化学检测系统
产品型号:
供应商报价:面议
产地:美国
发布时间:2023-08-07
所属分类:首页 > 分析仪器设备频道 > 动物实验仪器专场 > 电化学检测系统
  • 产品简介
  • 应用行业
  • 典型用户

快速扫描循环伏安法(FSCV)电化学检测系统,用于儿茶酚胺(i.e., dopamine, norepinephrine, and serotonin)的测量。可以用于测量自由清醒活动状态下的动物。该遥测系统适用于小鼠。

FAST SCAN CYCLIC VOLTAMMETRY SYSTEM

Pinnacle’s FAST SCAN CYCLIC VOLTAMMETRY (FSCV) SYSTEM is specifically designed to simplify the measurement of catecholamines (i.e., dopamine, norepinephrine, and serotonin). Pinnacle offers turn-key systems for both mice and rats. Both the wireless rat system and the tethered mouse system use carbon fiber sensors to enable short-term measurement in the brains of freely moving animals.

HOW IT WORKS

Biogenic amine levels are detected by rapidly cycling a voltage across an implanted carbon fiber sensor and measuring the resultant current. Our systems can measure spontaneous sub-second neurotransmitter release events while conducting detailed behavioral studies. Both the wireless and tethered systems sweep from 250 to 400 V/s in a user-selectable range spanning -1.1 to +1.3 V. All systems have built-in support for controlling an external stimulus.

l Voltage Span: -1.1 V to +1.3 V

l Range: 250 – 400 V/s

l Sweeps/second: 5 - 10

l Points/sweep: 1000

Analysis

Dopamine (blue), serotonin (green), and norepinephrine (pink) have specific voltammogram profiles when detected by FSCV.

The TETHERED FAST SCAN CYCLIC VOLTAMMETRY (FSCV) SYSTEM allows researchers to harness the powerful genetics of the mouse model to address underlying mechanisms of biogenic neurotransmitter release and function. A headmounted FSCV board sends signals through a low-torque commutator to an interface box that streams data to the host PC. The system comes with Pinnacle’s FREE 8500 software.

1. The FSCV interface box provides access to stimulus lines and transmits data to PAL-8500 software.

2. A low-torque commutator, which is mounted above the cage, allows for unencumbered freedom of movement.

3. Signals are amplified and filtered at the head of the animal using our headstage, which ensures the delivery of clean, artifact-free data.

4. Stereotaxically placed guide cannulas allow easy insertion of carbon fiber sensors. Headmounts are affixed to the skull with dental acrylic and act as a connection port for the headstage.

CARBON FIBER

Pinnacle’s FSCV system uses CARBON FIBER SENSORS (CFSs) to measure the presence of dopamine and other catecholamines in the brains of freely moving animals. Our sensor is a 34 μm diameter carbon fiber housed in a silica sheath that extends 0.5 mm beyond the end of the silica. All Pinnacle CFSs require an Ag/AgCl reference electrode.

Our sensor is a 34 um diameter carbon fiber housed in a silica sheath that extends 0.5 mm beyond the end of the silica.

CARBON FIBER SENSORS

Carbon fiber sensors are ordered by cannula type and whether the researcher needs to remove them from the cannula for post-calibration. CFS-F sensors are fixed in the cannula and cannot be removed for post-calibration。

FSCV PAL-8500 SOFTWARE PACKAGE

The FSCV system includes Pinnacle’s FREE PAL-8500 software, which supports traditional, short recording paradigms (recordings of two minutes or less) as well as longer-term recordings that use an extended continuous mode. Furthermore, the suite supports integrated, synchronized video recording, which allows monitoring of animal behavior simultaneously with biogenic amine release.

Additional features of this software include:

? Background Subtraction

? 3D Visualization

? User-Selectable Filters

? Heat Maps

? Animated Voltammograms

? Export to Third-Party Packages

请关注玉研仪器的更多相关产品。

如对产品细节和价格感兴趣,敬请来电咨询!

关于我们 - 服务专区 - 法律声明 - 诚征合作 - 友情链接 - 广告服务 - 付款方式 - 联系我们

中国粉体网 网上粉体展 版权所有

Powdershow.com.cn Copyright(C)2002-2013,All Rights Reserved

版权所有 未经书面授权,所有页面内容不得以任何形式进行复制