How does the Zeta-APS measure particle size distributions?
Zeta-APS如何测量粒度分布?
The Zeta-APS accurately measures acoustic attenuation (dB/cm) vs. frequency of sound (1 to 100 MHz) of colloidal dispersions. These measurements are commonly referred to as Acoustic Attenuation Spectroscopy. The Zeta-APS also simultaneously measures speed of sound vs. frequency, percent solids, pH, conductivity, and temperature. The attenuation level, as well as, the shape of the acoustic attenuation curve shape is related to the particle size distribution (PSD). PSD’s are calculated from the acoustic attenuation data using software developed and patented by Lucent Technologies. This Lucent Technologies software is based on the Epstein and Carhart (later refined by Allegra and Hawley) theory of acoustic attenuation.
Zeta-APS准确测量了胶体分散体的声衰减(dB/cm)与频率(1-100MHz)的关系。这些测量通常被称为声衰减谱。Zeta-APS可以同时测量声速、频率、固体百分比、pH值、电导率和温度。衰减水平以及声衰减曲线形状与颗粒粒径分布(PSD)有关。PSD是由Lucent Technologies开发并获得的软件。该软件基于Epstein和Carhart(后来由Allegra和Hawley改进)的声衰减理论。
How does the Zeta-APS measure Zeta Potential (ZP)?
Zeta-APS如何测量Zeta电位?
The Zeta-APS uses an electroacoustic technique called Electrokinetic Sonic Amplitude (ESA, invented by Matec Applied Sciences) to measure Zeta potential of particles suspended in liquids. The Zeta-APS’ Zeta sensor applies short highfrequency (AC) pulses to the sample located within the electrode region of the Zeta sensor. These pulses last about 30 micro-seconds in the frequency range 0.5-3.5 MHz. The particles “jiggle” back and forth due to their surface electric charge which produces an output sound wave of the same frequency as the applied sound wave-provided there is a particle/solvent density difference of at least 2%. The sample can be mixed and/or pumped during the measurement without interfering with the ESA measurement.
Zeta-APS测量Zeta电位的方法被称为电声振幅(ESA)。 Zeta-APS的Zeta电位探头将高频交流脉冲施加到位于传感器电极区域内的样品中,这些脉冲在0.5-3.5 MHz的频率范围内持续约30微秒。由于粒子的表面电荷会产生与所施加声波相同频率的输出声波,因此粒子来回“摆动”,粒子周围的介质对其将有阻力的影响,这种阻力会以声波的形式从粒子表面传播出来,电场内的粒子产生声波的叠加,形成超声波,其振幅就是电声振幅(ESA),通过ESA来计算Zeta电位。需要注意的是颗粒与介质的密度差至少为2%。 测量期间可以搅拌或泵送样品。
1495

- 1聚氨酯不含铜、锌等有害杂质
- 2苏州天启高速混合机手册
- 3纳米石墨烯电镜检测
- 4纳米石墨粉粒度检测(复达)25-0630
- 5电池材料表征实践指南
- 6聚合物加工测试分析指南
- 7散量秤彩页
- 8无斗定量包装秤—毛重秤彩页

- 为什么AFM、NC等期刊频繁报道多孔水凝胶的最新研究进展?
- 蓝宝石的10大应用
- 《JMST》顶刊揭秘:激光3D打印高强铝合金的“强韧协同”奥秘——协同晶粒细化策略
- NC、AFM等期刊报道银纳米线最新研究进展!
- 为什么ZIF-67的最新研究进展值得关注?
- 经典介孔分子筛SBA-15又有新进展!
- 利用蜂鸟声共振技术对穿心莲内酯纳米混悬剂的开发、表征和分子动力学模拟
- 为什么核壳复合纳米材料的研究进展值得关注?
- Development, Characterization, and Molecular Dynamics Simulation of Andrographolide Nanosuspensions Utilizing Hummer Acoustic Resonance Technology
- 苏州碳丰科技首席科学家程金生老师以本公司名义在国际上发表关于石墨烯纤维的论文《石墨烯纤维纳米复合材料的合成及氨基酸检测的分析应用》:
- 介可视·散装物料库存管理雷达全景扫描系统在料仓、堆场中的应用
- 磷酸化修饰鬼臼果多糖的制备及生物活性
- DSR论文解读:Advanced Science News 报道中科院长春应化所新型非铂催化材料研究成果
- High-throughput preparation, scale up and solidification of andrographolide nanosuspension using hummer acoustic resonance technology(纳米混悬剂制备的前瞻性技术 - 蜂鸟声共振)
- 扫描电镜优秀论文赏析|飞纳台式扫描电镜电极材料上的应用
- 扫描电镜论文赏析-干旱影响杨树叶片及次生木质部发育的分子机制